  VENTURA 20FP25H1CT-R Aerospace Cadmium Nickel Battery Pack Test and Inspection Report


  Product model:20FP25H1CT-R


  Voltage/Capacity:24V25Ah


  Equipped with temperature sensor


  Part number:3349025950


  Manufacturer:Ventura AERO


  Testing date:May 20,2026


  Test basis:EN 9100:2018,AS 9100-D-JISQ 9100:2016


  Test category:Factory inspection


  Qualification determination:Ac=0,Re=1


  Experimental project:


  Capacity:75.933,unit:min,room temperature:22℃,relative humidity:65%,termination voltage:20V,qualification standard:discharge time≥60min,conclusion:qualified


  Under the condition of 22℃,the battery pack is charged according to the prescribed method and left for 2 hours,then discharged at 25A until the termination voltage is 20V.


  At 23°C,after the battery pack is fully charged according to the technical specifications,it should be placed in a low-temperature box at-18°C for 16 hours,and then started three times according to the starting curve of 650A 1s 635A 4s 520A 5s 420A 10s 250A 10s 150A 10s 80A 5s,with an interval of 1 minute between each time.


  Conclusion:Ventura 20FP25H1CT-R aviation battery can achieve 3 starts of the aircraft in an environment of-18°C.